Product
Weighing
LC-4101 (Aluminum) | ||||||||||||||||||
For small capacity weighing applications,single point compact load cells | ||||||||||||||||||
|
||||||||||||||||||
|
||||||||||||||||||
Features | ||||||||||||||||||
Parallelogram-type construction Temperature compensation maintains both zero and span from -10 °C to +40 °C/+14 °F to +104 °F Deadweight up to 80% of capacity. Load weight and deadweight up to 180% of capacity Moisture proof Compact and lightweight Can be used for capacities as light as 600 g |
||||||||||||||||||
Specifications | ||||||||||||||||||
Rated capacities....................... 600 gf, 1.5 kgf, 3 kgf, 0 kgf,15 kgf Rated output ...............................1 mV/V+15/-0% Maximum deadweight ..............80% of rated capacity Maximum safe overload ..........300% of rated capacity Combined error ........................±0.015% of rated output Creep ..........................................±0.05% of rated output/hour Zero balance .............................20±5% of rated output Compensated temperature range.................. -10 °C to +40 °C/+14 °F to +104 °F Recommended excitation voltage .....................12 V Maximum excitation voltage .....................1 5 V Input terminal resistance....... Approximately 400 Ω Output terminal resistance ...350 Ω ± 5 Ω Insulation resistance .............Greater than 5000 MΩ at DC50 V Temperature effect Zero ...........................................0.004% of rated output/°C Span ..........................................0.0014% of rated output/ Type. Platform size ...........................300 × 300 mm/11.8 × 11.8 inches Cable length ............................1.5 m / 59 inches |
||||||||||||||||||
|